Articles
- For installing and removing the urinal flush control without removing the ceramic appliance, the urinal rim height must be at least 58 cm above finished floor
Sections:
My list (0)
Protection degree IP45 |
Nominal voltage 110–240 V AC |
Mains frequency 50–60 Hz |
Operating voltage 4.5 V DC |
Power consumption standby max. 0.1 W |
Flow pressure 1–8 bar |
Test pressure, water max. 16 bar |
Flush volume small, adjustment range 0.5 l |
Flow rate at 1 bar with flow limiter 0.18 l/s |
Minimum flow pressure 1 bar |
Interval flush time, factory setting 5 s |
Detection time, factory setting 7 s |
Flush time, adjustment range 1–15 s |
Flush time, factory setting 7 s |
Product material Sanitary ceramic |
Urinal flush control with power supply unit and solenoid valve
Fastening material
Urinal trap with suction function
Drain strainer
Drain assembly
Inlet set
Water pressure reducing valve
Your current privacy settings do not allow the use of this content. Do you want to activate the comfort/settings cookie category? For more information, please see the privacy policy.
# | Art. no. | Description | Remarks |
---|---|---|---|
1 | 243.332.00.1 | Geberit spray head, complete | |
1.1 | 243.334.00.1 | Geberit non-return valve for spray head | |
1.2 | 243.333.00.1 | Geberit spray head nozzle | |
51 Articles